Description
20 Collyer Quay Office for Rent
20 Collyer Quay previously known as Tung Centre is a 24-storey office block completed in 1984.
It overlooks Marina Bay, which is being transformed into an exciting and vibrant waterfront destination.
It is used primarily for office rental and sale.
The building has a very good office layout with maximum and efficient use of office space.
It is also equipped with basic amenities.
Being strategically located in near to Singapore’s Downtown Core is definitely a plus point for business startup here.
- Typical Floor Plate: Approx. 10,000sqft
- Floor Ceiling: 2.6m
- Cable Management: Under Floor Trunking System
- Lift:
Passenger Lifts: 8nos. (Car A to H)
Lifts to Carpark at B2 – 2 nos. (Car E & F)
Service Lift- 1nos. (Car I)
- Air- Conditioning
* Centralized chilled water system with two AHUs on each floor
* Operational hours from Monday to Fridays (7am to 7pm) and Saturdays (7am to 2pm)
* After office hours at $50/hour/AHU or tap into the condensed water in the AHU rooms.
Water Consumption at $1.00 per hour. Subject to prevailing GST and subject to change.
- Car Parking
* 1 lot for every 2,500sqft
* Total 106 season parking lots and 10 visitor lots
* Operating hours from 7am to 11pm (closed on Sunday and Public Holidays)
* Season parking rate at $300 per lot. Subject to prevailing GST. Subject to change.
* Hourly parking available at $2.50 per half hour or part thereof between 7am and 4.59pm.
Per entry fees of $3.20 starts from 5pm onwards. Subject to change.
- Building Security: 24- hour security system with CCTV monitoring at all main entrances and exits, card access control via turnstiles to lift lobbies.
- Washroom: Male and Female provided on every office floor
- Pantry: Common wet pantry every office floor
- Fire Protection:
* Fully sprinkled with hose reels, manual break glass, call points and wet riser landing valves installed at strategic locations on each floor.
* Smoke detectors are installed in electrical rooms.
* Automatic fire alarm system comprises sub-panels on each floor to monitor the alarms status of the floor and is linked to the main fire alarm panel on the ground floor.
The system is linked directly to the Decentralized Alarm Monitoring Systems (DECAMS) via telephone line.
- Telecommunication:
* Communication cable riser ducts are provided for Telecoms to run their main trunking cables and for installation of distribution boxes.
* Individual PABX systems and all telephone wirings have to be undertaken as part of fitting- out works and tenants will be required to make direct application to Telecoms.
- Electricity:
* 3 nos. of tenant electricity supply distribution boards are provided per typical floor.
* 60A single phase neutral (SPN) main supply is provided per distribution board.
- Emergency Power Supply: The essential building services like elevators, exit lightnings,
common area lightnings,
ventilation fans and other life safety equipment are fully backed up by a standby generator. - Floor Loading: Live Load: 3.0Kn/sqm; Partitions Load: 1.0Kn/sqm